WLAN overview


MSTKN-H-S14-HM-WLAN-GBA

The 4-slots Socket Trays was developed for use in industrial environments Socket Trays was developed for use in industrial environments. It is compatible with all common screwdriving systems and Control systems. The Tray has an internal bus system so that each main module can be operated with several extension modules. It is a Modbus TCP slave and can also be used in existing bus systems. The fieldbus interface communicates via WiFi with cyclical data transmission via Open Modbus TCP/UDP. The robust aluminum housing can withstand even the toughest conditions in the workplace.


MSTKN-H-S24-HM-WLAN-GBA

The 8-slots Socket Trays was developed for use in industrial environments. It is compatible with all common screwdriving systems and Control systems. The Tray has an internal bus system so that each main module can be operated with several extension modules. It is a Modbus TCP slave and can also be used in existing bus systems. The fieldbus interface communicates via WiFi with cyclical data transmission via Open Modbus TCP/UDP. The robust aluminum housing can withstand even the toughest conditions in the workplace.


MSTKN-H-S14-HM-WLAN-24V

The 4-slots Socket Trays was developed for use in industrial environments Socket Trays was developed for use in industrial environments. It is compatible with all common screwdriving systems and Control systems. The Tray has an internal bus system so that each main module can be operated with several extension modules. It is a Modbus TCP slave and can also be used in existing bus systems. The fieldbus interface communicates via WiFi with cyclical data transmission via Open Modbus TCP/UDP. The robust aluminum housing can withstand even the toughest conditions in the workplace.


MSTKN-H-S24-HM-WLAN-24V

The 8-slots Socket Trays was developed for use in industrial environments. It is compatible with all common screwdriving systems and Control systems. The Tray has an internal bus system so that each main module can be operated with several extension modules. It is a Modbus TCP slave and can also be used in existing bus systems. The fieldbus interface communicates via WiFi with cyclical data transmission via Open Modbus TCP/UDP. The robust aluminum housing can withstand even the toughest conditions in the workplace.

Feature Overview

Modbus Interface
The fieldbus interface communicates via WiFi with cyclical data transmission via Open Modbus TCP/UDP. The interface is compatible with class 0 with some class 2 extensions (FC23, read/write, multiple registers). The device has two words of process data available (one input and one output register), which are addressed as follows:

  • Read: Register address 512 (hex 0x200) contains the status of the socket head; the output register is read back via address 0
  • Write: Register address 0 (hex 0x000) sets the control register of the socket head.

The control register has two areas (1 byte each) for “Command” (bits 0-7) and “Selection” (bits 8-15). The status register is also divided into two parts: “Status” (bits 0-7) and “Selection” (bits 8-15).

Available versions

Socket Trays

type Description
Main module 24V EA Parallel interface
Main module 24V EA parallel interface, Open Protocol variant
Main module Profinet slave fieldbus interface
Main module Profibus slave fieldbus interface
Main module Ethernet/IP slave fieldbus interface
Main module EtherCAT fieldbus interface
extension module Modbus slave fieldbus interface